APRS World, LLC

Thermok Configuration Page

Home Products Ordering Information Order Tracking Photo Gallery Live Data Sites Contact Information

Thermok Home

Thermocouple Suggestions and Links

Sample Applications

User Manual (PDF)

Generate firmware image

Computer Interface Details

Embedded Source Code

Panel Mount Option

Schematic Diagram (PDF)

Data Graphing Instructions (PDF)

Using the form below you can generate a custom Thermok firmware image. You can then follow our bootloading instructions to download it to your Thermok.

Startup Message

This is the message that displays when the Thermok is powered on. It can be up to 16 characters long.

Temperature Units

The Thermok can display temperatures in degrees Celsius or Degrees Fahrenheit. Data transmitted on the serial port (computer interface) is always in degrees Celsius. The temperature display units can also be changed by holding the red button while powering up the Thermok.

Degrees Celsius
Degrees Fahrenheit

Alarm Active State

In an alarm condition the thermok can make an output active high or active low.

Active Low
Active High

Over temperature set points

The Thermok has two optional over temperature outputs. You can control the set point for each channel independently. These set points are in degrees Celsius.

Output A

1: 2:
3: 4:

Output B

1: 2:
3: 4:

Generate Firmware


APRS World, LLC - Contact Us